The server room serves as the backbone of a corporate IT infrastructure. An optimized server room design can save 20-30% in operational costs while ensuring mission-critical reliability. This article provides a detailed guide on server room design standards, from core requirements to cost-saving solutions. By applying these standards, businesses can achieve a technical space that is both high-performing and budget-optimized.

Efficient server room design saves corporate costs
Efficient server room design is a key driver for operational cost savings.

What is a Server Room? Its Vital Role in IT Ecosystems

A server room is a centralized data processing hub for a company’s critical IT assets. The spatial design of this room directly dictates the reliability of the entire IT network.

According to industry definitions, a server room is a dedicated, climate-controlled space designed for continuous operation of computer servers. While a standalone building for this purpose is a Data Center, interconnected rooms within a facility form a Server Farm.

Server room housing critical IT equipment
The server room centralizes a business’s most sensitive and vital IT equipment.
Function Impact Requirement
Data Processing Business Performance 99.99% Uptime
Information Storage Data Security Environmental Control
Network Connectivity Business Continuity N+1 Redundancy
System Security Information Safety Access Control

>> See more: Executive Office Design for Successful Leadership

The Essential Components of a Server Room

Performance depends on both high-end hardware and supporting infrastructure that meets rigorous reliability and energy efficiency standards.

  1. Power Infrastructure
    • UPS Online Double Conversion.
    • Backup Power Generators.
    • ATS (Automatic Transfer Switch).
    • Intelligent PDUs (Power Distribution Units).
  2. Cooling Systems
    • Precision Air Conditioning (PAC).
    • In-row cooling units.
    • Temperature and airflow sensors.
    • Airflow management (Hot/Cold aisle containment).
Server room cooling infrastructure
Specialized cooling systems are mandatory to maintain peak hardware performance.

7 Critical Standards for Server Room Design

1. Temperature and Humidity (ASHRAE Standards)

Following ASHRAE guidelines is crucial for IT longevity and energy costs. Monitoring helps detect “hot spots” before they cause equipment failure.

  • Operating Temperature: 18-27°C.
  • Relative Humidity (RH): 40-60%.
  • Dew Point: 5.5-15°C.
  • Max Temperature Change: <5°C per hour.

2. Spatial Planning and Location

Positioning influences maintenance costs and scalability. Space planning should account for 3-5 years of future growth.

  • Floor Space: ~2.5m² per standard rack.
  • Maintenance Aisle: Minimum 1m clearance.
  • Ceiling Height: Minimum 2.6m.

3. Fire Suppression Systems

Standard offices use water, but server rooms require Clean Agent Fire Suppression to protect electronics from water damage.

  • VESDA (Very Early Smoke Detection Apparatus).
  • FM-200 or NOVEC 1230 gas suppression.
  • Emergency Power Off (EPO) triggers.
  • Fire-rated walls and doors.

4. Raised Access Flooring Standards

Raised floors create a plenum space for efficient cable management and under-floor airflow.

  • Minimum Height: 600mm.
  • Load Capacity: 1200-1500 kg/m².
  • Anti-static properties.
  • F30+ Fire Resistance rating.

5. Power Continuity and Redundancy

Infrastructure must support 24/7 uptime. Redundancy tiers determine how the system handles outages.

System Technical Requirement Objective
UPS N+1 Redundancy Uninterrupted Power
Generator Startup time <30s Long-term Backup
PDU Real-time Monitoring Load Distribution

6. Precision Cooling vs. Comfort Cooling

Precision cooling is designed for high heat density and 24/7 operation, offering a much higher ROI compared to standard office ACs.

Precision cooling for server rooms
Precision cooling provides stable environments for sensitive IT hardware.

7. Connectivity and Structured Cabling (TIA-942)

Cabling must follow the TIA-942 standard to ensure scalability and prevent signal interference between power and data lines.

  • MDA (Main Distribution Area).
  • HDA (Horizontal Distribution Area).
  • EDA (Equipment Distribution Area).

Conclusion

Server room design is a balance of performance, reliability, and cost. By optimizing cooling and space, enterprises can reduce energy bills by 30-40% and maintenance costs by 15-20%.

Successful execution at Co-IDB combines the art of spatial design with the science of mission-critical engineering. Let us help you build a server room that meets both your technical needs and business goals.

>>> See more: Effective Meeting Room Design for Enterprises

|

Share

|
Author picture

Co-IDB Company

CO-IDB is an office furniture company following the Design & Build model. With project management capacity, its own production workshop and specialized technical team, CO-IDB is committed to providing optimal working space - right quality - on schedule.

CO-IDB is an office furniture company following the Design & Build model. With project management capacity, its own production workshop and specialized technical team, CO-IDB is committed to providing optimal working space - right quality - on schedule.

    Advise interior design and construction

    Leave your information and receive the earliest quote!




    Other news

    icon tròn trang trí website

    Đăng ký tư vấn